Combination Circuits/Schematics
Re: Combination Circuits/Schematics
Of course. As long as you know what is happening and how, it shouldn't be that much of a problem. Just be aware of it.
For example, the multiplexer without modification will send just one trigger over the line that is now active. With the modification, first a trigger is sent on the line that is now active, then a trigger on the line that is now inactive and lastly a trigger again on the line that is active.
It may confuse some circuits, so I wanted to point to it. But as said, if you are aware of it you can build upon it.
For example, the multiplexer without modification will send just one trigger over the line that is now active. With the modification, first a trigger is sent on the line that is now active, then a trigger on the line that is now inactive and lastly a trigger again on the line that is active.
It may confuse some circuits, so I wanted to point to it. But as said, if you are aware of it you can build upon it.
"There lies the dog buried" (German saying translated literally)
- tulamide
- Posts: 2714
- Joined: Sat Jun 21, 2014 2:48 pm
- Location: Germany
Re: Combination Circuits/Schematics
tulamide wrote:Of course. As long as you know what is happening and how, it shouldn't be that much of a problem. Just be aware of it.
For example, the multiplexer without modification will send just one trigger over the line that is now active. With the modification, first a trigger is sent on the line that is now active, then a trigger on the line that is now inactive and lastly a trigger again on the line that is active.
It may confuse some circuits, so I wanted to point to it. But as said, if you are aware of it you can build upon it.
Has this issue with regard to the Multiplex Primitive ever been brought to the attention of the developers?
Since a Multiplex Primitive that remember its input terminal value on all of its output terminals (even those it is not switched to) would be absolutely useless in the applications I am using it for - a piece of junk in the toolbox. Of course the triggers would be an issue in critical circuits and thank you for reminding us of that fact.
-
tiffy - Posts: 400
- Joined: Wed May 08, 2013 12:14 pm
Re: Combination Circuits/Schematics
tiffy wrote:
Has this issue with regard to the Multiplex Primitive ever been brought to the attention of the developers?
Since a Multiplex Primitive that remember its input terminal value on all of its output terminals (even those it is not switched to) would be absolutely useless in the applications I am using it for - a piece of junk in the toolbox. Of course the triggers would be an issue in critical circuits and thank you for reminding us of that fact.
I do know this has been known about for ages but it wouldn't hurt for you to email DSPR about it and let us know their comments, if any. This may be a good time to do it since they are developing 3.09 at the moment.
BUT maybe it's intentional and if so it would be nice to know the application for such behaviour. At present it works like a sample and hold multiplexor, i.e. you can distribute a value to any or all outputs and the values will hold. I used this technique in my analogue days to use just one DAC to control up to 8 oscillators. Any non-linearity in the DAC would then hold for all pitches produced. In that case the values distributed would be held on a capacitor until next addressed. Would this have any use in real-world applications in Flowstone?
Cheers
Spogg
-
Spogg - Posts: 3358
- Joined: Thu Nov 20, 2014 4:24 pm
- Location: Birmingham, England
Re: Combination Circuits/Schematics
Selector with Normal/Inverse Mode Drop list & Default Setting v1.42
There is also an option to send preset setting from a saved text file to the input terminal (you will need additional schematic to do this), and the start Index value for the drop list can be selected as well (0 or 1).
Description inside schematic.
There is also an option to send preset setting from a saved text file to the input terminal (you will need additional schematic to do this), and the start Index value for the drop list can be selected as well (0 or 1).
Description inside schematic.
- Attachments
-
- Selector with Nor-Inv mode Droplist v1.42.fsm
- (30.24 KiB) Downloaded 1227 times
-
tiffy - Posts: 400
- Joined: Wed May 08, 2013 12:14 pm
Re: Combination Circuits/Schematics
Wow ... nice improvements TIFFY !
I'm just starting to test, but looking good
definite for the ToolBox.
Thanks
---- EDIT ----
Am finding an issue with INPUT INDEX.
With a '0' Input, the selector goes to Item2.
still testing
I'm just starting to test, but looking good
definite for the ToolBox.
Thanks
---- EDIT ----
Am finding an issue with INPUT INDEX.
With a '0' Input, the selector goes to Item2.
still testing
- RJHollins
- Posts: 1571
- Joined: Thu Mar 08, 2012 7:58 pm
Re: Combination Circuits/Schematics
RJHollins wrote:Wow ... nice improvements TIFFY !
I'm just starting to test, but looking good
definite for the ToolBox.
Thanks
---- EDIT ----
Am finding an issue with INPUT INDEX.
With a '0' Input, the selector goes to Item2.
still testing
I think you misunderstood. You are confusing ITEM numbers (on the droplist) with INDEX numbers.
When you set the index to start counting from the value 0, and you set the default index to the value of 1, it will jump to the 2nd item on the drop list (on Ctrl + Left Mouse Click) which is index number 1 (not 0). Please note that item numbers may differ from index numbers.
When you set the index to start counting from the value 1 (then you start to count from 1 and not from 0), and if you still keep the default setting at a value of 1, it will jump to the 1st item on the drop list (on Ctrl + Left Mouse Click) which is still index number 1(i.e. now the 1st item, since you are ignoring 0... you are not counting from 0 now but from 1).
If you want ITEM numbers to correspond with INDEX numbers, you will have to number your ITEMS correspondingly. The DEFAULT setting is a INDEX setting and not a ITEM setting on the drop list.
Also note that the "Set Start position of Index (0 & 1)" setting is not the default setting, it is the position from where the index starts counting. The Default setting is clearly marked "Default" which means that is the INDEX position (not necessarily corresponding to ITEM position) it will jump to on a Ctrl + Left Mouse Click.
Check it out, there is nothing wrong with the schematic in that regard. But thanks, keep testing.
-
tiffy - Posts: 400
- Joined: Wed May 08, 2013 12:14 pm
Re: Combination Circuits/Schematics
oh ... ok, will check that out that way.
thanks Tiffy
thanks Tiffy
- RJHollins
- Posts: 1571
- Joined: Thu Mar 08, 2012 7:58 pm
1 x Sliding Window (Manual)
LDo Click + Drag Mouse Horizontally Left/Right on the Dark Black Horizontal line (Horizontal Slider) in the Schematic to slide the Window Open or Close respectively.
- Attachments
-
- 1 x Sliding Glass Window.fsm
- (8.84 KiB) Downloaded 1210 times
-
tiffy - Posts: 400
- Joined: Wed May 08, 2013 12:14 pm
2 x Sliding Windows (Manual)
LDo Click + Drag Mouse Horizontally Left/Right on the Dark Black Horizontal line (Horizontal Slider) in the Schematic to slide the Windows Open or Close respectively.
- Attachments
-
- 2 x Sliding Glass Windows.fsm
- (9.11 KiB) Downloaded 1230 times
-
tiffy - Posts: 400
- Joined: Wed May 08, 2013 12:14 pm
Re: Combination Circuits/Schematics
I got "error inside module" so is this with the 3.09 beta?
I like the idea but I can't play
Cheers
Spogg
I like the idea but I can't play
Cheers
Spogg
-
Spogg - Posts: 3358
- Joined: Thu Nov 20, 2014 4:24 pm
- Location: Birmingham, England