Ticks Question.
23 posts
• Page 2 of 3 • 1, 2, 3
Re: Ticks Question.
Like this. This blocks the triggers from the ticker when you do not have the vst editor open
- Attachments
-
- Capture.PNG (9.06 KiB) Viewed 11999 times
- adamszabo
- Posts: 667
- Joined: Sun Jul 11, 2010 7:21 am
Re: Ticks Question.
So, in one section I have 3 small level meters and 3 tiny scopes , showing an envelope signal.
When I shut down the ticker to the moving graphics CPU is 3% , when I turn it on its 8,5%.
I am using one 25 ticker to run these graphics. How can I optimize this or am I stuck with such a CPu usage when using moving graphics like meters and such ? Not sure if I am chasing my tail or if its possible to bring this down?
When I shut down the ticker to the moving graphics CPU is 3% , when I turn it on its 8,5%.
I am using one 25 ticker to run these graphics. How can I optimize this or am I stuck with such a CPu usage when using moving graphics like meters and such ? Not sure if I am chasing my tail or if its possible to bring this down?
-
lalalandsynth - Posts: 600
- Joined: Sat Oct 01, 2016 12:48 pm
Re: Ticks Question.
Thanks Adam , so this applies to the whole gui in the DAW rather then individual sections when not displayed ?
-
lalalandsynth - Posts: 600
- Joined: Sat Oct 01, 2016 12:48 pm
Re: Ticks Question.
Am I right in assuming that the redraw limiter might help here , does that shut down triggers when a particular part of the gui is not visible ?
-
lalalandsynth - Posts: 600
- Joined: Sat Oct 01, 2016 12:48 pm
Re: Ticks Question.
Interesting, with a few tweaks , shutting off tickers to sections, using the "change" I have managed to reduce the CPU by a considerable amount. I have noticed though that using meters is taking me from 3% to 8-9%.
How can I have responsive meters and reduce the cost?
This is common with all the modules and is indeed the cause for my high cpu.
I should be able to get it down to about 2-3% If I can reign back this meter CPU issue.
How can I have responsive meters and reduce the cost?
This is common with all the modules and is indeed the cause for my high cpu.
I should be able to get it down to about 2-3% If I can reign back this meter CPU issue.
-
lalalandsynth - Posts: 600
- Joined: Sat Oct 01, 2016 12:48 pm
Re: Ticks Question.
it's fine to use green for constants and maintain sample accuracy when plugged into stream,
Lalaland.
I'm not sure how to do the meter without looking at it- would you like to upload it?-
but yes the draw area and # of ticks?
It does use only one redraw?
Lalaland.
I'm not sure how to do the meter without looking at it- would you like to upload it?-
but yes the draw area and # of ticks?
It does use only one redraw?
-
nix - Posts: 817
- Joined: Tue Jul 13, 2010 10:51 am
Re: Ticks Question.
From my experience excessive CPU load in graphics is always a result of a tick avalanche in a green processing chain. For instance a binary operation will often output two ticks, hence all subsequent operations will be executed twice!. Stack a bunch of binary operators and your CPU will sweat (unnecessarily).
I can imagine that this may be the issue in your schematics but it is impossible to tell without seeing it.
I can imagine that this may be the issue in your schematics but it is impossible to tell without seeing it.
-
martinvicanek - Posts: 1328
- Joined: Sat Jun 22, 2013 8:28 pm
Re: Ticks Question.
I could upload of course but I am using the Alpha.
Any of you guys have the alpha ?
I could redo the meter in 3.09
Any of you guys have the alpha ?
I could redo the meter in 3.09
-
lalalandsynth - Posts: 600
- Joined: Sat Oct 01, 2016 12:48 pm
Re: Ticks Question.
Nix , Yes, it seems that constants are working but in this instance I am shifting an array with an lfo with a mono to float inbetween and this array shift affects audio and its not sample accurate , good enough for auditioning but does not work properly in faster then realtime render which is to be expected. , I am not sure how to do that to a stream without using greens.
-
lalalandsynth - Posts: 600
- Joined: Sat Oct 01, 2016 12:48 pm
Re: Ticks Question.
i did recreate this in the 3.09 version although in my Alpha schem I replaced the ballistics module with an envelope follower as the stock meter was disappearing on me at random with the original ballistics module.
THis does not seem to be the problem as the CPU hit can be seen in this example.
It might be this redraw thing, How do I make a single redraw for all meters ?
THis does not seem to be the problem as the CPU hit can be seen in this example.
It might be this redraw thing, How do I make a single redraw for all meters ?
-
lalalandsynth - Posts: 600
- Joined: Sat Oct 01, 2016 12:48 pm
23 posts
• Page 2 of 3 • 1, 2, 3
Who is online
Users browsing this forum: Google [Bot] and 168 guests