trogz tools...

For general discussion related FlowStone
Post Reply
tester
Posts: 1786
Joined: Wed Jan 18, 2012 10:52 pm
Location: Poland, internet

trogz tools...

Post by tester »

...may require some updates?

Different output vs different reading. Play with input values 0-2.
Attachments
cheating-fix.fsm
(4.62 KiB) Downloaded 1070 times
cheating.fsm
(4.58 KiB) Downloaded 932 times
Need to take a break? I have something right for you.
Feel free to donate. Thank you for your contribution.
User avatar
trogluddite
Posts: 1730
Joined: Fri Oct 22, 2010 12:46 am
Location: Yorkshire, UK

Re: trogz tools...

Post by trogluddite »

Well spotted! - very strange behaviour, usually it matches exactly with a regular trigger counter, and I can't make sense yet of why an extra S&H makes the difference!
All schematics/modules I post are free for all to use - but a credit is always polite!
Don't stagnate, mutate to create!
tester
Posts: 1786
Joined: Wed Jan 18, 2012 10:52 pm
Location: Poland, internet

Re: trogz tools...

Post by tester »

I bet that this might have something to do with recent FS updates. Thus - other tools might need to update too.

It partially works in SM, i.e. shows correct values but wrong amount of triggers. I remember there was some change in boolean and/or trigger behaviors between SM and FS3. BTW, why would you not add the S&H on input in your tools by default? Should not the inputs be rather separated from what comes in?
Attachments
partial-works-in-sm.zip
(5.7 KiB) Downloaded 944 times
Need to take a break? I have something right for you.
Feel free to donate. Thank you for your contribution.
User avatar
MyCo
Posts: 718
Joined: Tue Jul 13, 2010 12:33 pm
Location: Germany
Contact:

Re: trogz tools...

Post by MyCo »

I've isolated the issue. The "Last Switch" primitive somehow blocks duplicated triggers (or maybe it limits the frequency). I've attached a demonstration.

As far as I can remember, this is a new behaviour. Don't think that this is correct.

Edit: Last S|M Version has the same behaviour... so this change was long time ago.
Attachments
duplicate trigger issue (MyCo).fsm
(1.03 KiB) Downloaded 963 times
tester
Posts: 1786
Joined: Wed Jan 18, 2012 10:52 pm
Location: Poland, internet

Re: trogz tools...

Post by tester »

Somehow "switch" behaves logical to me. It reduces... "entangled triggers" :mrgreen:
(a series of triggers associated with 1 value resend?).

But more seriously. If the issue is the same in SM and FS, then why Troggies tool behaves differently in SM and differently in FS?

So it looks, that besides the trigger queue - there might be something else (a marker), that determines triggers as separate "dots" or as a "series". That behavior would explain why adding a timer for "trigger separation" I used in some places - makes the change no mattero how rediculous it sounded.
Need to take a break? I have something right for you.
Feel free to donate. Thank you for your contribution.
Post Reply